Xiang Welding Industrial Co Ltd
AWS A5.5 / ASME SFA5.5 E9016-G
JIS Z3211 E5716
EN ISO 2560-A - E50 2 B 1 2
Notes on Usage
Welding Positions:
① Dry the electrodes at 350~400 ℃(662~752℉) for 60 minutes before use.
② Adopt back step method or strike the arc on a small steel plate prepared for this particular purpose because arc striking on the base metal is in danger of initiating cracking.
③ Keep the arc as short as possible.
④ Preheat at 60~80℃(140~176℉) before use. The temperature to be applied varies in accordance with plate thickness and steel kind.
⑤ If each pass welds becomes thicker than acceptable level by high amperage of low speed ratio manipulation, the impact values and yield points will decrease.
Applications
AWS A5.5 / ASME SFA5.5 E9016-G can be used for welding of high tensile steel such as pressure vessels, bridges, rolling stock, and machines using steel plates of high tensile steel.
Welding Position
Characteristics on Usage
·Good workability in all positions.
·Stable arc.
·Excellent mechanical properties and X-ray performance.
Current
AC or DC +